Difference between revisions of "Optotrak"

From TSG Doc
Jump to navigation Jump to search
 
(6 intermediate revisions by 3 users not shown)
Line 1: Line 1:
 +
{{Infobox tsg
 +
| name          = Optotrak Certus
 +
| image          = Optotrack certus.jpg
 +
| caption        = Optotrak Certus
 +
| manuals        = {{See_also|#Manuals}}
 +
}}
  
== Optotrack Certus ==
+
The Optotrak Certus is an optical motion tracking system. It uses active infrared markers.
  
[[image:ndi.jpg | thumb]]
+
<!-- Table of Contents will be generated here -->
  
[[image:Optotrack certus.jpg|400px|Image: 400 pixels]]
+
<!-- ==Specifications== to be added -->
  
== Startup Sequence ==
 
  
[[Media:OptotrakStartupSequence.docx]]
+
==Usage==
 
+
===Startup===
 
+
# Turn on power rails.
'''Optotrak Startup Sequence'''
 
 
 
# Turn on powerrails.
 
 
# Turn on computers and log in.
 
# Turn on computers and log in.
 
# Turn on ODAU unit (when used) and wait for it to beep. If the ODAU unit is not used, don’t turn it on.
 
# Turn on ODAU unit (when used) and wait for it to beep. If the ODAU unit is not used, don’t turn it on.
Line 20: Line 22:
 
# Turn on Control Unit and wait for it to beep.
 
# Turn on Control Unit and wait for it to beep.
 
# Start First Principles and load your First Principles experiment. The used units will beep.
 
# Start First Principles and load your First Principles experiment. The used units will beep.
# When not all used units are found, make sure that the units you use are turned on, and that all other units are turned off. Close First Principles an restart First Principles. If still not all used units are found, press the button labeled ‘Query system’. If that still doesn’t find all units, contact Hubert Voogd from TSG.
+
# When not all used units are found, make sure that the units you use are turned on, and that all other units are turned off. Close First Principles an restart First Principles. If still not all used units are found, press the button labeled ‘Query system’. If that still doesn’t find all units, contact [[Hubert Voogd]] of the TSG.
 
# Align Sensor Units (when using more than one sensor unit).
 
# Align Sensor Units (when using more than one sensor unit).
 
# Define coordinate system.
 
# Define coordinate system.
Line 26: Line 28:
 
# Place IRED markers on subject, AFTER BEING SURE THAT THE IREDS ARE NOT GETTING TOO HOT!
 
# Place IRED markers on subject, AFTER BEING SURE THAT THE IREDS ARE NOT GETTING TOO HOT!
  
== Manuals ==
+
([[Media:OptotrakStartupSequence.docx|Printable version]])
 +
 
 +
==Performing a registration and alignment==
 +
 
 +
*[[Media:OptotrakRegistration.pdf | Performing a registration and alignment (pdf)]]
 +
 
 +
==Custom Interface==
 +
You can create your own software to communicate with the Optotrak System, both directly and via First Principles. We advice to use First Principles to record your data and communicate with First Principles by using the RTC3D protocol. Find more information and resources in the links below.
 +
 
 +
*[[Media:Optotrak_Application_Programmers_Interface_Guide(IL-1070086).pdf | Optotrak Application Programmers Interface Guide]]
  
*[[Media:First_Principles_User_Guide(IL-1070104_Rev3).pdf]] First Principles User Guide
+
*[[Media:RTC3D_protocol_rev4.pdf | RTC3D Protocol]]
  
*Optotrak Certus User Guide rev 6: [[Media:Optotrak_Certus_User_Guide_rev_6(IL-1070106).pdf]]
+
*[[Media:RTC3D_client_for_customers.zip | RTC3D examples]]
  
*Optotrak Certus Marker Strober Guide: [[Media:Optotrak_Certus_Marker_Strober_Guide(IL-1070074).pdf]]
+
*[[Media:ClientSocketsPackage.zip | Delphi component for connecting to First Principles using RTC3D]] <ref name="source">Can also be used as a source base to write code in other languages.</ref> (by [[Hubert Voogd]])
  
*Optotrak Certus Tool Strober Guide: [[Media:Optotrak_Certus_Tool_Strober_Guide(IL-1070076).pdf]]
+
*[https://github.com/wilberth/Rudolph/blob/master/fpclient.py Python module for connecting to First Principles using RTC3D] <ref name="source" /> (by [[Wilbert van Ham]])
  
*Optotrak Certus 3020 Strober Adapter Guide: [[Media:Optotrak_Certus_3020_Strober_Adapter_Guide(IL-1070075).pdf]]
+
==Manuals==
 +
*[[Media:First_Principles_User_Guide(IL-1070104_Rev3).pdf | First Principles User Guide]]
  
*Optotrak Data Acquisition Unit II Guide (ODAU unit): [[Media:Optotrak_Data_Acquisition_Unit_II_Guide(IL-1070028).pdf]]
+
*[[Media:Optotrak_Certus_User_Guide_rev_6(IL-1070106).pdf | Optotrak Certus User Guide (rev. 6)]]
  
*NDI 6D Architect User Guide (usefull for making rigid body files): [[Media:NDI_6D_Architect_User_Guide(IL-1070059).pdf]]
+
*[[Media:Optotrak_Certus_Marker_Strober_Guide(IL-1070074).pdf | Optotrak Certus Marker Strober Guide]]
  
*How to make Rigid Body files, RIG File Creation Procedure: [[Media:NDI_LS Division-RIG_File_Creation_Procedure_R1.1.pdf]]
+
*[[Media:Optotrak_Certus_Tool_Strober_Guide(IL-1070076).pdf | Optotrak Certus Tool Strober Guide]]
  
*NDI DataView User Guide: [[Media:NDI_DataView_User_Guide(IL-1070088).pdf]]
+
*[[Media:Optotrak_Certus_3020_Strober_Adapter_Guide(IL-1070075).pdf | Optotrak Certus 3020 Strober Adapter Guide]]
  
*Optotrak Application Programmers Interface Guide. Usefull when you are creating your own software that communicates with the Optotrak System. We advise however to use First Principles to record your data and communicate with First Principles by using the RTC3D Protocol that is descibed in the link below this one. [[Media:Optotrak_Application_Programmers_Interface_Guide(IL-1070086).pdf]]
+
*[[Media:Optotrak_Data_Acquisition_Unit_II_Guide(IL-1070028).pdf | Optotrak Data Acquisition Unit II Guide (ODAU unit)]]
  
*RTC3D Protocol, use this protocol when you write your own software, to communicate with First Principles. [[Media:RTC3D_protocol_rev4.pdf]]
+
*[[Media:NDI_6D_Architect_User_Guide(IL-1070059).pdf | NDI 6D Architect User Guide]] (useful for making rigid body files)
  
*RTC3D examples: [[Media:RTC3D_client_for_customers.zip]]
+
*[[Media:NDI_LS Division-RIG_File_Creation_Procedure_R1.1.pdf | RIG File Creation Procedure]] (more on rigid body creation)
  
*Delphi Component that implements an RTC3D client that can connect to First Principles. Written by Hubert Voogd. Can also be used as a source base to write code in other languages. [[Media:ClientSocketsPackage.zip]]
+
*[[Media:NDI_DataView_User_Guide(IL-1070088).pdf | NDI DataView User Guide]]
  
*Python code that implements an RTC3D client that can connect to First Principles. Written by Wilbert van Ham. Can also be used as a source base to write code in other languages. https://github.com/wilberth/Rudolph/blob/master/fpclient.py
+
==References==
 +
<references />

Latest revision as of 10:48, 7 October 2022

Optotrak Certus
Optotrack certus.jpg
Optotrak Certus
Manuals
See also: § Manuals

The Optotrak Certus is an optical motion tracking system. It uses active infrared markers.



Usage

Startup

  1. Turn on power rails.
  2. Turn on computers and log in.
  3. Turn on ODAU unit (when used) and wait for it to beep. If the ODAU unit is not used, don’t turn it on.
  4. Turn on Sensor Unit 1 and wait for it to beep. Remove caps.
  5. Turn on Sensor Unit 2 (when used) and wait for it to beep. Remove caps. If sensor unit 2 is not used, don’t turn it on.
  6. Turn on Control Unit and wait for it to beep.
  7. Start First Principles and load your First Principles experiment. The used units will beep.
  8. When not all used units are found, make sure that the units you use are turned on, and that all other units are turned off. Close First Principles an restart First Principles. If still not all used units are found, press the button labeled ‘Query system’. If that still doesn’t find all units, contact Hubert Voogd of the TSG.
  9. Align Sensor Units (when using more than one sensor unit).
  10. Define coordinate system.
  11. Connect IRED markers.
  12. Place IRED markers on subject, AFTER BEING SURE THAT THE IREDS ARE NOT GETTING TOO HOT!

(Printable version)

Performing a registration and alignment

Custom Interface

You can create your own software to communicate with the Optotrak System, both directly and via First Principles. We advice to use First Principles to record your data and communicate with First Principles by using the RTC3D protocol. Find more information and resources in the links below.

Manuals

References

  1. 1.0 1.1 Can also be used as a source base to write code in other languages.