BrainStreamExampleSpellerPart1: Difference between revisions
Jump to navigation
Jump to search
Wiki-admin (talk | contribs) |
Wiki-admin (talk | contribs) No edit summary |
||
| Line 20: | Line 20: | ||
Below, a flowchart of the Train block is shown: | Below, a flowchart of the Train block is shown: | ||
[[File: | [[File:DocsSectionsExampleSpellerPart1_flowchart.png|656px|261x]] | ||
''Figure 1: Flowchart'' | ''Figure 1: Flowchart'' | ||
| Line 32: | Line 32: | ||
A [[BrainStreamPlugIns|imported] table (StimDisplay in speller_common) is used to define all actions related to stimulus presentation. You can see the reference to this imported table in the 9th row of the main Actions table: '@speller_common.edt StimDisplay'. The imported table is shown below: | A [[BrainStreamPlugIns|imported] table (StimDisplay in speller_common) is used to define all actions related to stimulus presentation. You can see the reference to this imported table in the 9th row of the main Actions table: '@speller_common.edt StimDisplay'. The imported table is shown below: | ||
[[File: | [[File:DocsSectionsExampleSpellerPart1_speller_common_actions_2.png|832px|167x]] | ||
''Figure 2: StimDisplay imported table.'' | ''Figure 2: StimDisplay imported table.'' | ||
| Line 66: | Line 66: | ||
As explained in the introduction, the visual speller is based on the brain response to the flashing rows and columns. Therefore, we need to collect a certain amount of data after each flash. The highlightGrid function (see the [[#StimPres|Stimulus presentation section]]), inserts a marker highlightOn each time a row or column of the grid is highlighted. As we need accurate synchronization with the data, this marker is inserted [[BrainStreamMarkerHandling#HardwareMarker|via the hardware]]. Data selection is specified for the highlightOn marker in the speller_common import-table. This is the import-tables' [[BrainStreamBuildingExperiments#SecDataSel|DataSelection table]: | As explained in the introduction, the visual speller is based on the brain response to the flashing rows and columns. Therefore, we need to collect a certain amount of data after each flash. The highlightGrid function (see the [[#StimPres|Stimulus presentation section]]), inserts a marker highlightOn each time a row or column of the grid is highlighted. As we need accurate synchronization with the data, this marker is inserted [[BrainStreamMarkerHandling#HardwareMarker|via the hardware]]. Data selection is specified for the highlightOn marker in the speller_common import-table. This is the import-tables' [[BrainStreamBuildingExperiments#SecDataSel|DataSelection table]: | ||
[[File: | [[File:DocsSectionsExampleSpellerPart1_speller_common_data.png|456px|53x]] | ||
''Figure 4: DataSelection table'' | ''Figure 4: DataSelection table'' | ||