'''-TemplateINFO.pcl''' | |||
output_port Oport = output_port_manager.get_port( 1 ); | output_port Oport = output_port_manager.get_port( 1 ); | ||
Oport.send_code(100); | '''-TemplateSUBS.pcl''' | ||
wait_interval(2); | |||
Oport.send_code(0); | Oport.send_code(100); ''#This is your marker code, range code 1-255'' | ||
wait_interval(2); ''#2ms delay for the code to be recorded by brainvision; 2ms->500hz sampling rate'' | |||
Oport.send_code(0); ''#Back to 0; now ready to send a new code'' | |||
== Python == | == Python == | ||
Revision as of 07:33, 1 May 2014
Brainvision
Software Documentation
Find the Brainvision analyzer manual here Media:BrainVision_Analyzer_UM.pdf
Find the Brainvision recorder manual here Media:BrainVision_Recorder_UM.pdf
Find the Brainvision macro cookbook manual here Media:Macro_Cookbook.pdf
Find the Brainvision RecView manual here Media:BrainVision_RecView_UM.pdf
Find the Brainvision Automation manual here Media:Automation_Reference_Manual.pdf
EEG Markers
Presentation
-TemplateINFO.pcl
output_port Oport = output_port_manager.get_port( 1 );
-TemplateSUBS.pcl
Oport.send_code(100); #This is your marker code, range code 1-255
wait_interval(2); #2ms delay for the code to be recorded by brainvision; 2ms->500hz sampling rate
Oport.send_code(0); #Back to 0; now ready to send a new code