Difference between revisions of "Brainvision"

From TSG Doc
Jump to navigation Jump to search
m
 
(One intermediate revision by one other user not shown)
Line 2: Line 2:
 
| name          = Brainvision
 
| name          = Brainvision
 
| image          = Logo brainproducts.png
 
| image          = Logo brainproducts.png
| caption        = <br />Files provided on your Wiki page are neither provided by Brain Products nor up to date; The most current versions of all these files can be found on the brain products website at<br />https://www.brainproducts.com/downloads.php<br />
+
| caption        = <br />Files provided on your Wiki page are neither provided by Brain Products nor up to date; The most current versions of all these files can be found on the brain products website at<br />https://www.brainproducts.com/downloads.php<br /><br />
 
| downloads      = {{bulleted list
 
| downloads      = {{bulleted list
   | [https://surfdrive.surf.nl/files/index.php/s/LN5KRN9cB3mvPp3 Brainvision Analyzer] (zip)
+
   | [https://surfdrive.surf.nl/files/index.php/s/PZ3WfwtnClCkVhs Installs and Manuals]
  | [https://surfdrive.surf.nl/files/index.php/s/LN5KRN9cB3mvPp3 Brainvision Recorder] (zip)
 
  }}
 
| manuals        = {{bulleted list
 
  | [https://surfdrive.surf.nl/files/index.php/s/LN5KRN9cB3mvPp3 Brainvision Analyser Manual]
 
  | [https://surfdrive.surf.nl/files/index.php/s/LN5KRN9cB3mvPp3 Brainvision Recorder Manual]
 
  | [https://surfdrive.surf.nl/files/index.php/s/LN5KRN9cB3mvPp3 Brainvision Macro Cookbook Manual]
 
  | [https://surfdrive.surf.nl/files/index.php/s/LN5KRN9cB3mvPp3 Brainvision RecView Manual]
 
  | [https://surfdrive.surf.nl/files/index.php/s/LN5KRN9cB3mvPp3 Brainvision Automation Manual]
 
 
   }}
 
   }}
 
}}
 
}}

Latest revision as of 13:05, 11 June 2024

Brainvision
Logo brainproducts.png

Files provided on your Wiki page are neither provided by Brain Products nor up to date; The most current versions of all these files can be found on the brain products website at
https://www.brainproducts.com/downloads.php

Downloads

Electroencephalography is the neurophysiological measurement of electrical activity in the brain as recorded by electrodes placed on the scalp or, in special cases, subdurally or in the cerebral cortex. The resulting traces are known as an electroencephalogram (EEG) and represent a summation of post-synaptic potentials from a large number of neurons.

The use of EEG in neuroscience research delivers a number of benefits. One is that EEG is non-invasive for the research subject. Furthermore, the need to restrict the subject‘s movements is clearly lower than in other fields of neuroscience such as functional magnetic resonance imaging (fMRI). A further benefit is that many EEG applications record spontaneous brain activity, which means that the subject does not need to be able to cooperate with the researcher (as is necessary, for instance, during behavioral testing in neuropsychology). Also, EEGs have a high temporal resolution compared with techniques such as fMRI and PET and are capable of detecting changes in electrical activity in the brain on a time scale in the millisecond region.

In conventional scalp EEG, the recording is obtained by applying electrodes to the scalp using a conductive gel or paste, usually after preparing the scalp area by light abrasion to reduce electrode-scalp impedance. Many systems typically use electrodes which are each attached to an individual wire. Some systems use caps in which electrodes are embedded. This latter method is particularly common when high-density arrays of electrodes are required.

In addition to internal artifacts such as those produced by blinking, there are many artifacts which originate from outside the patient. Movement by the patient generates huge artifacts. Sweating or changes in temperature may cause electrode drifts. Spikes can originate from a momentary change in impedance at a given electrode. Poor grounding of the EEG electrodes can cause significant 50 or 60 Hz artifacts arising from the power system‘s frequency.

Brain Products EEG amplifiers are equipped with a number of noise reduction techniques such as active noise cancellation and active electrodes. High common mode rejection as well as low amplifier noise ensure maximum data quality. Our huge product range includes a range of electrodes and caps with custom or standard montages as well as a variety of requisite accessories.

Digital Port Settings (Markers/Buttonbox)

DigitalPort.jpg

Interface BITSIbox

For the settings of the interface and to send the markers go to: http://tsgdoc.socsci.ru.nl/index.php?title=ButtonBoxes

Presentation

In the BITSI simple protocol you will have to reset the code manually to 0. BITSI simple code:

1#TemplateINFO.pcl
2
3output_port Oport = output_port_manager.get_port( 1 );
4
5#TemplateSUBS.pcl
6
7Oport.send_code(100);  #This is your marker code, range code 1-255
8wait_interval(4);      #4ms delay for the code to be recorded by brainvision; 2ms->500hz sampling rate so 2 samples available
9Oport.send_code(0);    #Back to 0; now ready to send a new code

In BITSI extended protocol the reset is done by a specific time set with the capital "T". BITSI extended:

 1#TemplateINFO.pcl
 2
 3output_port Oport = output_port_manager.get_port( 1 );
 4
 5#TemplateSUBS.pcl
 6
 7#only specify this ones, then its valid for the full experiment
 8Oport.send_string("T");  #Specify the pulse length time
 9Oport.send_code(4);    #4ms delay for the code to be recorded by brainvision; 2ms->500hz sampling rate so 2 samples available
10
11Oport.send_string("P");  #Specify its a pulse you want to send out
12Oport.send_code(100);    #This is your marker code, range code 1-255
13#Now it resets itself automatically to 0 after the specified time

Python

 1#!/usr/bin/env python
 2
 3# import the rusocsci.buttonbox module
 4from rusocsci import buttonbox 
 5
 6# make a buttonbox
 7bb = buttonbox.Buttonbox()
 8
 9# wait for a single button press
10bb.sendMarker(100)    #This is your marker code, range code 1-255
11core.wait(0.002)      #2ms delay for the code to be recorded by brainvision; 2ms->500hz sampling rate
12bb.sendMarker(0)      #Back to 0; now ready to send a new code

BrainVision Recorder - Default Workspace

Audience:

All BrainVision Recorder users

Description

To make sure all data acquired at the DCC can be utilized for extensive analysis, default settings (sample rate, filters and such) are recommended for all EEG experiments. These settings have to be specified in the Workspace of the BrainVision Recorder package (screenshots of the BrainVision Recorder program are used below to illustrate how one can enter the settings correctly into the workspace).

Download workspace BrainVision Recorder

Links and Documentation For the standard 32 and 64 electrode setup, workspaces are available here.

Find the Brainvision analyzer manual here Media:actiCAP-32Ch-standard workspace DCC_new.zip

Find the Brainvision analyzer manual here Media:actiCAP-64Ch-standard workspace DCC_new.zip

Please check the BrainVision Recorder manual (English / German) for more in depth details.

Defining a workspace in BrainVision Recorder

The default settings required for EEG experiments have to be specified in the Workspace of the BrainVision Recorder package. This can be done as follows. Make a copy with a new name of an existing workspace file. Default 32 and 64 channel workspace files can be found on the data drive, D:\Workfiles\.

  • Open the BrainVision Recorder package on the EEG computer in the lab of your choice by double clicking on the icon.
  • Go to File / Open Workspace and open your workspace file.
  • Go to File / Edit Workspace.
  • The following window will appear on the computer screen:

1.gif


In this window one defines the directory to which the raw datafiles have to be written. Always choose D:\Raw Files\<your name>\.... You can also use the option Automatic Filename Generation if you wish to have the names of your raw data files to be automatically generated. Please note that your workspace may contain valuable information about your EEG-configuration. Always keep a copy of the workspace file with your raw data! Never leave your data on the EEG-PC. Always copy data immediately after your experiment to your network drive. Every two weeks your data will be erased automatically.

Good practice directly after your experiment:

  • Ensure you have a copy of your workspace file
  • Copy your data to your network drive or an external harddrive
  • Make an archive-copy of your raw data files according to the archiving policy in your PI-group.
  • Delete your data files from the local disk of the EEG-PC. Files will be erased automatically!

AMPLIFIER SETTINGS:

Click on the button "next", the following window appears on your screen:

Image: 600 pixels


First press "Scan for Amplifiers". BrainVision Recorder will give an overview of the amplifiers the software is communicating with. The following default DCC settings are recommended for all channels.

Setting Default
Nr. of channels to be used []
Sampling rate (=downsampling filter) 500Hz
Resolution 0.1 μV
Low Cutoff 10 s (frequency 0.016 Hz)
High Cutoff (= anti-aliasing filter) 1000 Hz
Low impedance Switched OFF.
Use individual settings Only use this option to specify the electrode names of the electrode arrangement of your choice.

SOFTWARE FILTERS:

Click on the button Next, the following window appears on your screen.

Image: 600 pixels


PLEASE NOTE THAT THIS CARD HAS THREE TABS!


TAB1: "Raw data saving filters" The following default settings are recommended for all channels:

Setting Default DCC settings
Enable filters Switched ON
Low Cutoff Filter 10s (frequency 0.016 Hz)
High Cutoff Filter 125 Hz
Notch Filter Switched OFF
Use Individual Settings Switched OFF

Note 1:

Sampling of the EEG is done by the amplifier with 5000Hz fixed and either 1000Hz anti aliasing filter (normal) or 250Hz anti aliasing filter (MRI only!). Downsampling can be done realtime on the computer to 200, 250, 500, 1000, 2500 or 5000. An appropriate anti-aliasing filter should be selected for that as well, depending on the downsampling frequency. At the default sampling rate of 500Hz, use a cutoff frequency not higher than 200Hz.

Note 2:

Skin impedance should be kept low, e.g. below 20kΩ. We are currently looking into the possibility of running experiments with high skin impedance.

TAB2: "Segmentation filters"

Click on the tab "Segmentation Filters", the following window appears on your screen.

4.gif


On this page filters can be specified for all data that is segmented/averaged online.

Since we recommend to collect all data in the continuous mode, these filters do not have to be specified and the "Enable Filters" option should be switched off.

TAB 3: "Display filters"

Click on the tab "Display Filters", the following window appears on your screen.

5.png


These filters are only set for display. It is recommended to set the filters in exactly the same way as the "Raw Data Saving Filters" so that you see is what you get. Thus, the following default settings are recommended:

Setting Default
Enable filters Switched ON
Low Cutoff Filter 10s (frequency 0.016 Hz)
High Cutoff Filter 125 Hz
Notch Filter Switched OFF
Use Individual Settings Switched OFF

SEGMENTATION / AVERAGING:

Click on the button "next", the following window appears on your screen:

6.gif


On this page settings can be specified for online segmentation/averaging of EEG data. Since we recommend to collect all data in the continuous mode, these settings do not have to be specified and the "Enable Filters" option should be switched off. However, if one would like to see an average of their data on screen, just for display purposes, one can enter the settings here (and the filter specifications for the segmented data in the "Segmentation Filters" tab (described above)). Please check the BrainVision Recorder manual (English / German) for more in depth details.