+ | = EEG Markers = | ||
+ | |||
+ | == Presentation == | ||
+ | #TemplateINFO.pcl | ||
+ | output_port Oport = output_port_manager.get_port( 1 ); | ||
+ | |||
+ | #TemplateSUBS.pcl | ||
+ | Oport.send_code(100); #This is your marker code, range code 1-255 | ||
+ | wait_interval(2); #2ms delay for the code to be recorded by brainvision; 2ms->500hz sampling rate | ||
+ | Oport.send_code(0); #Back to 0; now ready to send a new code | ||
+ | |||
+ | == Python == |
Revision as of 08:29, 1 May 2014
Brainvision
Software Documentation
Find the Brainvision analyzer manual here Media:BrainVision_Analyzer_UM.pdf
Find the Brainvision recorder manual here Media:BrainVision_Recorder_UM.pdf
Find the Brainvision macro cookbook manual here Media:Macro_Cookbook.pdf
Find the Brainvision RecView manual here Media:BrainVision_RecView_UM.pdf
Find the Brainvision Automation manual here Media:Automation_Reference_Manual.pdf
EEG Markers
Presentation
- TemplateINFO.pcl
output_port Oport = output_port_manager.get_port( 1 );
- TemplateSUBS.pcl
Oport.send_code(100); #This is your marker code, range code 1-255 wait_interval(2); #2ms delay for the code to be recorded by brainvision; 2ms->500hz sampling rate Oport.send_code(0); #Back to 0; now ready to send a new code