Changes

Jump to navigation Jump to search
503 bytes removed ,  13:43, 18 January 2021
no edit summary
Line 4: Line 4:  
| caption = TMS in 2018
 
| caption = TMS in 2018
 
| label1 = Location
 
| label1 = Location
| data1 = B.00.30
+
| data1 =  
 
| manuals = {{bulleted list
 
| manuals = {{bulleted list
     | [[:File:MagProX100.pdf|MagPro X100 specification]]
+
     | [https://surfdrive.surf.nl/files/index.php/s/B3YSjFcp3UUdRbq regulations brain stimulation]
     | [[:File:Magpro_family.pdf|MagPro family User Guide]]
+
    | [https://surfdrive.surf.nl/files/index.php/s/B3YSjFcp3UUdRbq MagPro X100 specification]
 +
     | [https://surfdrive.surf.nl/files/index.php/s/B3YSjFcp3UUdRbq MagPro family User Guide]
 
     }}
 
     }}
 
}}
 
}}
Line 39: Line 40:     
Information sheets on how to use the Localite are available in the TMS lab. The complete Localite manual is available at the labmanager (Dennis Schutter).
 
Information sheets on how to use the Localite are available in the TMS lab. The complete Localite manual is available at the labmanager (Dennis Schutter).
 +
 +
[[File:TMS.JPG|thumb|left|300px|TMS]]<br clear=all>
    
==NeuroConn Transcranial Electric Current Stimulation==
 
==NeuroConn Transcranial Electric Current Stimulation==
microprocessor controlled constant current source
+
# microprocessor controlled constant current source
1 channel, anodal and cathodal stimulation possible
+
# 1 channel, anodal and cathodal stimulation possible
use of external trigger possible, several AC-DC-STIMULATOR devices can be synchronized for multichannel stimulation
+
# use of external trigger possible, several AC-DC-STIMULATOR devices can be synchronized for multichannel stimulation
adjustable current up to 5,000 µA (±1%)
+
# adjustable current up to 5,000 µA (±1%)
adjustable application time up to 30 min
+
# adjustable application time up to 30 min
please note: currents of more than 1,000 µA and application times of more than 15 min are for research purposes only!
+
# please note: currents of more than 1,000 µA and application times of more than 15 min are for research purposes only!
modes of stimulation:  
+
# modes of stimulation:  
o single (continuous stimulation, freely adjustable fading in and fading out)
+
## single (continuous stimulation, freely adjustable fading in and fading out)
o pulses (cyclic turning on and off of the stimulation, defined pulse width and interstimulus intervall ISI)
+
## pulses (cyclic turning on and off of the stimulation, defined pulse width and interstimulus intervall ISI)
o customer specific programs possible (e.g. sine wave, half-sine wave etc.)
+
## customer specific programs possible (e.g. sine wave, half-sine wave etc.)
high safety standard through multistage monitoring of output current
+
# high safety standard through multistage monitoring of output current
STUDY MODE OPTION
+
# STUDY MODE OPTION
INTERNAL & EXTERNAL TRIGGER MODULE
+
# INTERNAL & EXTERNAL TRIGGER MODULE
 
Technical data
 
Technical data
135 mm x 225 mm x 55 mm (W x D x H); weight 0.9 kg
+
# 135 mm x 225 mm x 55 mm (W x D x H); weight 0.9 kg
12bit D/A conversion
+
# 12bit D/A conversion
power consumption approx. 0.4 W
+
# power consumption approx. 0.4 W
power supply via built-in rechargeable batteries, incl. external charger
+
# power supply via built-in rechargeable batteries, incl. external charger
alphanumeric display with backlight
+
# alphanumeric display with backlight
 +
 
 +
[[File:NeuroConn.JPG|thumb|left|300px|NeuroConn]]<br clear=all>
    +
==EEG 128Ch brainproducts==
   −
==summary==
+
[[Brainvision|Brainvision info page]]
*[[Computers#Lab Computer|Dell T3600]]
  −
*[[Monitors|Benq XL2420Z]]
  −
*[[Computers#Keyboard|Corsair Vengeance K70 Keyboard]]
  −
*[[Computers#Mouse|Logitech G500 and G700 mice]]
  −
*AudioEngine A2 Speakers
     −
{| class="wikitable"
+
[[File:BrainKast.jpg|thumb|left|300px|Kijkje achter de schermen]]<br clear=all>
|-
  −
|-
  −
! Lab Equipment ||Specification
  −
! scope="row" colspan="1"|
  −
|-
  −
| Type || Optical, 16 Cameras
  −
|-
  −
| Accuracy (mm) || 0.75 - 3.0 || <1.0
  −
|-
  −
| Update Rate (Hz) || 180 || 60
  −
|-
  −
| Tracking || polaris spectra
  −
|-
  −
| EEG equipment || 128 ch 
  −
|-
  −
! Virtual Reality
  −
! scope="row" colspan="2" |
  −
|-
  −
| Wireless VR || style="background-color:#F99;" | No || style="background-color:#9F9;" | Yes
  −
|-
  −
| Stimulus PC || [[Dell_Precision_T-series#T3610|Dell Precision T3610]] || [[RIVER Labs#Stimulus PC (RIVER Lab 2)|See below]]
  −
|-
  −
| Stimulus Software || colspan="2" style="text-align:center"| [http://www.worldviz.com/products/vizard Worldviz Vizard 4.0], [https://unity3d.com/ Unity]
  −
|}
      
==References==
 
==References==
 
<references />
 
<references />

Navigation menu